Model |
6805 |
6810 |
6820 |
6830 |
6840 |
INPUT |
Phase |
1 phase |
Voltage |
115/230Vac ± 15% |
230Vac ± 15% |
Frequency |
47-63Hz |
OUTPUT |
Max. Power |
500VA |
1000VA |
2000VA |
3000VA |
4000VA |
Max Current(r.m.s) |
0-150V |
4.2A |
8.4A |
16.8A |
25.2A |
33.6A |
0-300V |
2.1A |
4.2A |
8.4A |
12.6A |
16.8A |
Max Current(r.m.s) |
0-300V |
2.1A |
4.2A |
8.4A |
12.6A |
16.8A |
Opt. 0-600 V |
0-600V |
1.05A |
2.1A |
4.2A |
6.3A |
8.4A |
Phase |
1 phase / 2W |
Total Harmonic Distortation (T.H.D) |
<=0.5% at 45-500Hz (Resistive Load) |
Crest Factor |
>= 4 |
Line Regulation |
±0.1V |
Load Regulation |
<=0.5% (Resistive Load) |
Response Time |
< 100µS |
SETTING |
Voltage |
Range |
0-150V / 0-300V Selectable or |
0-300V / 0-600V Selectable (Option 0 -600V) |
Resolution |
0.1V |
Accuracy |
±(0.5% of setting +2 counts) |
Frequency |
Range |
45-500Hz |
Resolution |
0.1Hz at 45.0-99.9Hz , 1Hz at 100-500Hz |
Accuracy |
±0.02% of setting |
Frequency |
Range |
45-1000Hz |
(Option 45Hz - 1KHz) |
Resolution |
0.1Hz at 45.0-99.9Hz , 1Hz at 100-1000Hz |
|
Accuracy |
±0.02% of setting |
MEASUREMENT |
Frequency |
Range |
0.0-500.0Hz |
Resolution |
0.1Hz |
Accuracy |
±0.1Hz |
Voltage |
Range |
0.0-300.0V / 0.0-600.0V |
Resolution |
0.1V |
Accuracy |
± (0.5% of reading +2 counts) for 0-300V |
± (0.5% of reading +4 counts) for 0-600V |
Current(r.m.s) |
Range |
L |
0.000-3.500A |
H |
3.00-35.00A |
Resolution |
L |
0.001A |
H |
0.01A |
Accuracy |
L |
± (0.5% of reading +5 counts) |
H |
± (0.5% of reading + 3 counts) |
Power |
Range |
L |
0.0-350.0W |
H |
300-4000W |
Resolution |
L |
0.1W |
H |
1W |
Accuracy |
L |
± (0.6% of reading +5 counts) |
H |
± (0.6% of reading +2 counts) |
Power Factor |
Range |
0.000-1.000 |
Resolution |
W / VA ,Calculated and displayed to three significant digits |
Accuracy |
GENERAL |
Low Range Meter |
Range : 2.0mA - 350.0mA / 0.20 - 35.00W |
(for 6805/ 6810 Option) |
Resolution : 0.1mA / 0.01W |
|
Accuracy : ± (0.6% of reading +5 counts). |
Remote Input Signal Interface |
Test, Reset, Recall memory 1 through 7 |
(Option) |
Remote Output Signal |
Fail ,Test-in Process |
Over Current Fold Back |
On/Off , Setting On when output current over setting A-Hi value |
it will fold back output voltage to keep constant output current is setting A-Hi value. |
Protection |
OCP, OTP ,OVP and Alarm |
Safety |
TUV/GS pending |
Dimension(W x H x D) mm |
430 x 89 x 400,2U |
430 x 89 x 560,2U |
430 x 267 x 650,6U |
430 x 667 x 650,15U |
430 x 667 x 650,15U |
Net Weight |
25Kg |
36Kg |
90Kg |
165Kg |
192Kg |
Operation Environment |
0-40°C / 20-80%RH |